Medister Steam Sterilizer
Technique | Features | Applications | Optional Features
 

Introduction:


Machin Fabrik's MEDISTER range of steam sterilizers is a product of world class engineering to meet your every sterilization need. A wide range of options available in capacity and automation make it suitable for all medical institutions from nursing homes to large multi-specialty hospitals.


Technique:

H.P.H.V/ Steam Sterilizers- the technique initiates with mechanical air removal from within the chamber utilizing a vacuum system followed by steam injection that comprises the sterilization cycle.

The purpose of vacuum creation is to prevent any existence of air pockets that can hamper the steam penetration and hence the sterilization process
.


Top


Features:

At Machinfabrik our autoclaves are built to the highest level of quality assurance to meet custom defined requirements.

1. Assured +/- 0.5 degree celsius temperature uniformity throughout the sterilization chamber.Baffle arrangement within the chamber to ensure uniform distribution of steam in the chamber.

2. The sterilization chamber is fabricated of ss316, non-corrosive and sanitary grade stainless steel. The chamber is double walled with a heavy duty steel jacket. This ensures rapid pre-heating and uniform temperature in the chamber. The chamber if required can be provided with a skid framework and a flush mounted SS panel is provided on the sterile side to isolate it from the non-sterile side.

3. PLC based control system for comprehensive automatic monitor and control of the process. User friendly operator interface terminal to allow the operator visual inspection and control of the process status .Rs232 port available with the plc to allow printing facility provision for recording of process operation and also for validation of the cycles.

4. Safety:
- Safety Valves for Chamber and Jacket.
- Door Obstruction- the door will not open when the chamber is pressurized.
- Both doors will not operate simultaneously to protect the integrity of sterile chain.
- 0.01 micron clean air filter for exhaust of the chamber from vacuum condition.

Top


Applications:

Sterilization of wide range of hospital instruments and accessories like surgical instruments, glassware, rubber and plastics, linen etc. at a temperature of 121 deg C and 134 deg C.

Top


Optional Features:

Steam Generator
· HPHV can be provided with an optional Steam Generator for independent and economic operation.
· The Steam Generator is made of SS304/316 as per requirement. (36 kW)
· Restricted upto a chamber size of 900 X 900 X 1200

Top

IS0 9001 CERTIFIED
Copyright 2004 MACHINFABRIK. Developed By P2S